Bally-refrigerated-boxes SmartVapElectronically Controlled System Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Ledničky Bally-refrigerated-boxes SmartVapElectronically Controlled System. Bally Refrigerated Boxes SmartVapElectronically Controlled System User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 8
  • Tabulka s obsahem
  • ŘEŠENÍ PROBLÉMŮ
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
SmartVap
TM
Electronically
Controlled System
Model: (Part # 1090200)
Electrical Power: 115/1/60, 208-230/1/60
1079817
PROGRAM SPECIFICATIONS
AND OPERATING
INSTRUCTIONS
Factory Settings:
This Defrost/Temperature control has been
COMPLETELY pre-set at the factory for Electric
Defrost mode. Room temperature default
factory setting is –10ºF. Simply re-adjust if
different room temperature setting is required.
If desired, clock can be set to display the
current time (24 hour mode)
. It is recommended
to retain all other factory settings initially, and
re-adjust accordingly later, if required.
Also refer to control wiring diagrams on
following pages.
Note: After power - up, allow 15 seconds for
display to activate
“Time” Button Functions
To view TIME settings (in sequence listed below),
push and release the “Time” button
To adjust settings, hold down the “Time” button
while pushing “Up” or “Down” buttons.
Electronic Room Thermostat & Defrost Control
Electric Defrost Mode Program
Default DISPLAY shows actual room (zone)
temperature:
Display Adjustment Factory
Function Shows: Range: Default
Setting:
24 hour time
“24:00”
00:00 to
NA
of day
24:00
Number of
defrosts per “nd / 04” nd01 to 12 nd / 04
day (24 hrs)
First defrost “def 01 / 00:00 to
09:00
start time 09:00” 24:00
Maximum
“defd / 35”
1 min. to
35 min.
defrost duration 2 hours
NATIONAL
REFRIGERATION
Note: To gain access to control buttons, pry
up cover (use slot at bottom of cover)
Display shows: Range:
-10ºF” -45ºF to 99ºF
Zobrazit stránku 0
1 2 3 4 5 6 7 8

Shrnutí obsahu

Strany 1 - REFRIGERATION

SmartVapTMElectronicallyControlled SystemModel: (Part # 1090200)Electrical Power: 115/1/60, 208-230/1/601079817PROGRAM SPECIFICATIONSAND OPERATINGINST

Strany 2

“Temp” Button FunctionsTo view TEMP settings (in sequence listed below), push and release the “Temp” button.To adjust settings, hold down the “Temp” b

Strany 6 - Troubleshooting Guide

Troubleshooting GuideWARNING: These guidelines are intended only for qualified service personnel familiar withtroubleshooting procedures and high volt

Strany 7 - Possible Solutions

ProblemRefrigeration cycle willnot start (Display OK andpowers up)Defrost heaters do not ener-gize (Display OK and powersup)Poor Refrigeration /Defros

Strany 8 - PROJECT INFORMATION

Due to National Refrigeration’s policy of continuous product improvement, we reserve the right to make changes without notice.metsySrebmuNledoM pU-tra

Komentáře k této Příručce