Bally-refrigerated-boxes 1000 Northwind Blast Chiller Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Ledničky Bally-refrigerated-boxes 1000 Northwind Blast Chiller. Bally Refrigerated Boxes 1000 Northwind Blast Chiller User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 17
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
1
Installation and Operation Manual
Northwind Blast Chiller
Models: 500 and 1000
1-800-24 BALLY
Bally Refrigerated Boxes, Inc.
www.ballyrefboxes.com
IM-359-11 2011© Bally Refrigerated Boxes, Inc
.
Zobrazit stránku 0
1 2 3 4 5 6 ... 16 17

Shrnutí obsahu

Strany 1 - 1-800-24 BALLY

1 Installation and Operation Manual Northwind Blast Chiller Models: 500 and 1000 1-800-24 BALLY Bally Refrigerated

Strany 2 - Introduction

10 deflecting the flow of air from the fan frame assembly to the coil frame assembly. Prior to installing, prepare 1/8” pilot holes and use ¾” stainl

Strany 3 - Table of Contents

11 7.3 Installing the Fan Frame Assembly 1. First remove the fan guard. 2. Install the frame in the appropriate side and screw the back braces to

Strany 4

12 7.5 Installing the Plenum Supports and Plenum 1. At this point, the Front Plenum Support, Fan Seal Strip, and Coil Top Trim should be in place. A

Strany 5 - Bally Northwind Tool List

13 *The priority should be in that order, if the Coil Top Trim holes won’t match up when the plenum is screwed to the Front, unscrew the Coil Frame fr

Strany 6 - 2. Panel Preparation

OPERATIONAL MANUAL: BALLY NORTHWINDS BLAST CHILLERBEFORE TURNING THE CONTROLLER ON, ensure that all wire connections are secure and correctly color c

Strany 7

6. The Display Screens in Automatic Mode:While in automatic, you can push the Next/Previous buttons on the display to page through information approp

Strany 8

Northwinds Blast Chiller Operations Manual 2013 © Bally Refrigerated Boxes, Inc. 16Screen Reads Appears When Measured Temperatures: Show temperatu

Strany 9

A Northwind 500 Model is shown. A Northwind 1000 Model is twice as deep. Northwinds Blast Chiller Operations Manual 2013 © Bally Refrigerated Boxes,

Strany 10

2 Introduction READ ENTIRE MANUAL BEFORE BEGINNING INSTALLATION! • There are 9 steps to the installation process. This manual gives you a corre

Strany 11

3 Table of Contents Title Page Number Introduction 1 Tool List 4 Parts List 4

Strany 12

4 Note: 012993’s are sometimes left out (see Chapter. 6.3)

Strany 13 - Installing Refrigeration

5 Bally Northwind Tool List Two people are required to assemble a Bally Northwind. The following list will assist you on the tools necessary in the

Strany 14

6 1. Locating the Blast Chiller 1.1. Using a chalk line and a carpenter’s square, locate on the building floor, the exact dimensions of the blas

Strany 15

7 3. Erection of Vertical Panels 3.1 BEFORE ATTEMPTING TO ERECT ANY PREFAB SECTIONS, FAMILIARIZE YOURSELF WITH THE FOLLOWING CHAPTERS IN THE STAN

Strany 16

8 3.3 On each panel, check for proper alignment and level. Leveling can be accomplished by placing wooden shims under the vertical panels (cross-r

Strany 17

9 5. Secure all Panel Sections 5.1 After all Speed-Loks are secured, install access hole plug buttons to all Speed-Lok locations. 5.2 Anchor both

Komentáře k této Příručce