Bally-refrigerated-boxes Walk-In Service Manual Uživatelský manuál

Procházejte online nebo si stáhněte Uživatelský manuál pro Ledničky Bally-refrigerated-boxes Walk-In Service Manual. Bally Refrigerated Boxes Walk-In Service Manual User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 10
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. 1
SERVICE MANUAL
WALK-IN COOLERS AND FREEZER
IM-268S-11
Routine maintenance 2
Safety Walk Strips 2
Gaskets
Replacing magnetic gasket on hinged Walk-In doors 3
Replacing wiper gasket at bottom of hinged Walk-In door 3
Hinged Walk-In Doors
Replacing the D-1000 touch latch on Walk-In doors 4
Replacing D-1250 spring loaded hinges on Walk-In door panels 5
Shimming Walk-In door hinges 5
Anti-Condensate Heaters
Replacing anti-condensate heater element around door frame of hinged Walk-In doors 6
Reach-In Doors
Replacing magnetic gasket on hinged Reach-In doors 7
Adjusting self-closing hinges on Reach-In doors 7
Replacing hinges on Reach-In door panels 8
Replacing anti-condensate heater element around frame of hinged Reach-In doors 8
Pressure Relief Port
Replacing klixon on Pressure Relief Port 9
Replacing anti-condensate heaters on Pressure Relief Ports 9
Replacing magnetic gasket on Pressure Relief Ports 9
Door Closer
Replacing Door Closer 10
Zobrazit stránku 0
1 2 3 4 5 6 7 8 9 10

Shrnutí obsahu

Strany 1 - IM-268S-11

REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. 1 SERVICE MANUAL WALK-IN COOLERS AND FREEZER IM-268S-11 Routine maintenanc

Strany 2 - Figure 1

10 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. Replacing Door Closer A. Position a putty knife against the base of the bottom of the clos

Strany 3 - GASKETS

2 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. ROUTINE MAINTENANCE A. Keep all walkway surfaces clean and free of spilled liquids and fo

Strany 4 - HINGED WALK-IN DOORS

REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. 3 GASKETS Replacing magnetic door gasket on Hinged Walk-In doors A. Remove t

Strany 5 - Shimming Walk-In door hinges

4 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. HINGED WALK-IN DOORS Replacing the D-1000 touch latch on Walk-Ins A. Remove the defective

Strany 6 - Walk-In doors

REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. 5 Replacing D-1250 spring-loaded hinges on Walk-In door panels A. Close t

Strany 7 - REACH-IN DOORS

6 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. ANTI-CONDENSATE HEATER Replacing anti-condensate heater element around door frame of hinged

Strany 8 - Figure 11

REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. 7 REACH-IN DOORS Replacing magnetic gasket on Reach-In doors A. To replace t

Strany 9 - Pressure Relief Ports (PRP)

8 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. Replacing hinges on Reach-In door panels A. Close the door and shim the cap securely aroun

Strany 10 - Replacing Door Closer

REV: 5/2013 IM-268S-11 2013 © Bally Refrigerated Boxes, Inc. 9 Pressure Relief Ports (PRP) Replacing magnetic gasket on PRP A. Remove the

Komentáře k této Příručce

Žádné komentáře